Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Korean J Ophthalmol ; 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38665112

RESUMO

Purpose: To assess efficacy, safety, and tolerability of the preservative-free fixed-dose combination of tafluprost 0.0015%/timolol 0.5% (PF tafluprost/timolol FC) in treatments-naïve patients with primary open-angle glaucoma (POAG). Methods: This was a retrospective, real-world clinical practice setting study that included 107 eyes of 107 subjects with POAG who had never been treated for glaucoma. All subjects were received PF tafluprost/timolol FC once daily. Intraocular pressure (IOP) levels were documented for each eye at the untreated baseline and up to six months after the initiation of medical treatment. All adverse events, including ocular and systemic adverse reactions, were recorded. Additionally, the reasons for medication discontinuations were thoroughly documented. Results: A total of 32 POAG patients with high-baseline IOP (> 21 mmHg) and 75 with normal-baseline IOP were included in the study. The subjects' baseline mean age was 62.4 ± 8.7 (range: 26 - 85 years); among them, 42 were women (39.3%). Mean IOP at baseline for all patients was 18.6 ± 4.3 mmHg. The mean IOP at six months was 12.6 ± 4.7 mmHg, representing a significant decrease compared to the baseline (-32%; P< 0.001). In POAG patients with high-baseline IOP, mean IOP was significantly lowered from 28.0 ± 5.7 mmHg at baseline to 18.0 ± 5.5 mmHg (-35%; P< 0.001); in patients with normal-baseline IOP, from 14.6 ± 3.4 mmHg to 10.3 ± 4.1 mmHg (-29%; P< 0.001). PF tafluprost/timolol FC was well tolerated and safe. After 6 months, 97.2% of all patients remained on therapy. Conclusions: In this real-world observational study, once-daily treatment with PF tafluprost/timolol FC demonstrated clinically relevant and statistically significant efficacy, as well as safety and good tolerability, in treatment-naive patients diagnosed with POAG.

2.
Dent Mater ; 40(4): 653-663, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38378372

RESUMO

OBJECTIVE: This study aimed to compare the four-point flexural strength of CAM-milled and sintered (as-sintered, AS) specimens with those of high-polished (HP) specimens using chairside polishing systems to simulate clinical surface conditions. METHODS: Seven full-contour zirconia CAM/CAM blanks with various yttria contents (3, 4, 5 mol%) including three high-translucent groups (5Y) were selected to prepare flexural specimens. The bend bar specimens (2.0 × 4.0 × 25.0 mm3) were fabricated by using STL file and dental CAM machine with the respective zirconia blanks (98 mm ϕ and 10-14 mm in height). Twelve bar specimens were machined from one zirconia puck and a total of 24 specimens were prepared from each group. The pre-sintered bar specimens were sintered by using a dental zirconia furnace at 1530-1550 °C for 2 h according to the instructions. All sintered specimens were divided into two groups: as-sintered (AS) group and high-polished (HP) groups (n = 12). HP groups were subjected to polishing one surface of specimens using a three-step polishing system and finally finished with diamond polishing. After cleaning and drying, the flexural strength of all specimens was determined by a fully articulating four-point flexure fixture consisting of a 1/4-point test configuration with an inner/outer span of 10/20 mm. Statistical differences between AS and HP groups were conducted with Weibull analysis. The fractured surfaces of zirconia specimens were observed using a field emission SEM and EDS to detect failure origins. RESULTS: The mean AS flexural strength values were significantly lower than those of HP counterparts. However, Weibull moduli expressing the reliability of HP groups were generally decreased although not significantly in comparison to their AS. The fracture of the AS specimens mostly originated from extrinsic CAM-milling defects, while the HP specimens were fractured from intrinsic subsurface or volume defects including pores, large grain clusters, inclusions, and corner-located critical flaws. Two high-translucent (5Y) zirconia groups were not affected in their strength and reliability after polishing, whereas one 5Y zirconia significantly increased its strength but significantly lowered its reliability. SIGNIFICANCE: The extrinsic and intrinsic strength-limiting defects should be considered in evaluating the flexural strength and reliability of dental CAD/CAM zirconia ceramics for full-contour restorations. For the materials tested in this study, more optimized processing of blanks and milling protocols of pre-sintered zirconia blanks should be developed including post-sintering surface finishing to reduce the flaw population regulating strength and reliability which will affect the survivability of dental zirconia prostheses.


Assuntos
Cerâmica , Materiais Dentários , Teste de Materiais , Reprodutibilidade dos Testes , Zircônio , Propriedades de Superfície , Ítrio
4.
Am J Dent ; 36(6): 267-273, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38092744

RESUMO

PURPOSE: To evaluate the amount of dentin loss following immersion in or toothbrushing with whitening toothpaste (WT) containing hydrogen peroxide (HP) and citric acid (CA). Additionally, the amount of dentin loss after brushing with a WT alone or in combination with a conventional toothpaste was assessed, and the effects of HP and CA solutions on the dentin surface were investigated. METHODS: Bovine dentin specimens (n= 350) were randomly assigned to seven solutions of various compositions as toothpaste: The specimens assigned to each solution were then further divided into five treatment groups (n=10 each) : Group A = 1-hour immersion in each solution (ES); Group B = 10,000 brushing in ES; Group C = 1-hour immersion in ES + 10,000 brushing in ES; Group D = 1-hour immersion in ES + 10,000 brushing in reference slurry (RS); Group E = 10,000 brushing in ES + 10,000 brushing in RS. The amount and pattern of dentin loss were determined, and the surfaces were observed using noncontact profilometry. RESULTS: The WT (pH 5.0) caused lower dentin loss than RS after a single brushing cycle; however, the extent of dentin loss after 1 hour of immersion in the WT was significantly greater than that in the RS. Among the specimens treated with WT, a significant difference in dentin loss was observed between Group C and Groups D and E (P< 0.05) but not between Groups D and E. The surfaces exposed to CAS1, CAPB, and WT exhibited U-shaped patterns of dentin loss after brushing or immersion, whereas a wedge-shaped pattern was observed in those that underwent brushing with the RS. CLINICAL SIGNIFICANCE: The effects (dentin abrasion) of a whitening toothpaste containing hydrogen peroxide and citric acid when used in combination with a conventional toothpaste were similar to those seen with the continuous use of a conventional toothpaste alone.


Assuntos
Abrasão Dentária , Erosão Dentária , Animais , Bovinos , Humanos , Cremes Dentais/efeitos adversos , Abrasão Dentária/induzido quimicamente , Peróxido de Hidrogênio/efeitos adversos , Escovação Dentária/efeitos adversos , Ácido Cítrico/efeitos adversos , Dentina
5.
Int. j. morphol ; 41(5): 1501-1507, oct. 2023. ilus
Artigo em Inglês | LILACS | ID: biblio-1521012

RESUMO

SUMMARY: As one of the suprahyoid muscles, the digastric muscle is characterized by two separate bellies of different embryologic origins. The origin of the anterior belly is the digastric fossa, while the origin of the posterior belly is the mastoid notch. They share a common insertion: the intermediate tendon. When the digastric muscle contracts, the hyoid bone is raised. Opening of the jaw and swallowing of food boli are associated with digastric muscle activity. This review discusses the general anatomic features of the digastric muscle and its variation, primary functions, and clinical implications focused on surgical reconstruction and rejuvenation.


Como uno de los músculos suprahioideos, el músculo digástrico se caracteriza por dos vientres separados, de diferentes orígenes embriológicos. El origen del vientre anterior es la fosa digástrica, mientras que el origen del vientre posterior es la incisura mastoidea. Comparten una inserción común, El tendón intermedio. Cuando el músculo digástrico se contrae, el hueso hioides se eleva. La apertura de la mandíbula y la deglución del bolo alimenticio se asocian con la actividad del músculo digástrico. Esta revisión analiza las características anatómicas generales del músculo digástrico y su variación, funciones primarias e implicaciones clínicas centradas en la reconstrucción y el rejuvenecimiento quirúrgico.


Assuntos
Humanos , Músculos do Pescoço/anatomia & histologia , Músculos do Pescoço/fisiologia
6.
BMC Oral Health ; 23(1): 619, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37658357

RESUMO

BACKGROUND: Hydrogen peroxide (HP) and citric acid (CA), key contributors to toothpaste acidity, can lead to dental loss. This study aimed to compare the amount of abrasion or loss of dentin based on pH, buffering, and concentration of HP and CA in commercial and experimental toothpastes after toothbrushing or immersion. METHODS: Bovine dentin specimens were randomly assigned to nine solutions. The prepared solutions included two commercial toothpastes (whitening toothpaste [WT] with HP and CA; conventional toothpaste [CT] without HP and CA), reference slurry (RS), two CA solutions (1.92%, CAS1; 0.001%, CAS2), basic solution (7.16% sodium phosphate dibasic [SPDS]), CA phosphate buffer solution (3.58% SPDS and 0.96% CA [CAPB]), HP solution (4%, HPS), and distilled water (DW). Dentin specimens were performed in two treatments: one with only abrasion (10,000 brushings) and one with only immersion (1 h). After treatments, the amount of dentin loss and surface images were measured and observed using noncontact profilometry. Data were analyzed using an one-way analysis of variance and the Tukey test as a post hoc analysis (p < 0.05). RESULTS: WT with pH 5.0 had lower dentin abrasion than CT and RS after brushing but had higher dentin loss than both after immersion. The dentin surfaces of CAS1, CAPB, and WT were damaged after immersion, whereas HPS, CAS2, CT, SPDS, RS, and DW remained intact after soaking. CAS2 and HPS, which had a pH of 5.0 like WT, did not significantly differ from those of DW after brushing. CONCLUSIONS: WT containing HP and CA did not cause significant dentin abrasion but may cause additional dentin loss even without brushing. After brushing or immersion, the CA concentration may affect the dentin surface more than the HP concentration included in WT. The amount of abrasion or loss of dentin after brushing or soaking can vary based on the composition, concentration, and buffer in the solution, even if the pH of the solution is similar to pH 5.0.


Assuntos
Peróxido de Hidrogênio , Cremes Dentais , Humanos , Animais , Bovinos , Cremes Dentais/efeitos adversos , Ácido Cítrico/efeitos adversos , Dentina
7.
Am J Dent ; 36(2): 55-61, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37076293

RESUMO

PURPOSE: To compare the amount of abrasion of four whitening toothpastes, two conventional toothpastes, and seven experimental toothpastes with varying concentrations of hydrogen peroxide. METHODS: Bovine dentin specimens were treated with the four whitening toothpastes (containing three different concentrations of hydrogen peroxide: 0.75%, 1.50%, and 2.80%), two conventional toothpastes without hydrogen peroxide, seven experimental toothpastes (concentrations of hydrogen peroxide: 0.75%, 1.50%, 3.0%, 4.50%, 6.0%, 7.50%, and 9.0%), and distilled water. After 10,000 strokes of toothbrushing, the amount of abrasion on the dentin surface was measured with a contactless 3D surface profiler (n= 8). The pH of all solutions, the weight percentages of the particles, and the component of particles in the toothpaste were analyzed. The correlations between the dentin abrasion, pH, and weight percentages of the particles in the toothpastes were investigated. RESULTS: The amount of abrasion of the two conventional toothpastes were 1.1-3.6 times higher than those of the four whitening toothpastes. Likewise, the pH of the conventional toothpaste was higher than those of the other whitening toothpastes. No significant differences were found among the four whitening toothpastes. The four whitening toothpastes consisted of a relatively lower weight percentage of particles compared to the two conventional toothpastes. A strong positive correlation was observed between the dentin abrasion and the weight percentages of the particles (r= 0.913; P< 0.05). Furthermore, no significant differences in the amount of abrasion were observed between the specimens treated with seven experimental toothpastes and those treated with distilled water. CLINICAL SIGNIFICANCE: The whitening toothpastes containing less than 9% hydrogen peroxide did not seem to harm the dentin surface significantly. These findings can serve as a reference for consumers, patients, and dental professionals.


Assuntos
Peróxido de Hidrogênio , Abrasão Dentária , Cremes Dentais , Abrasão Dentária/induzido quimicamente , Peróxido de Hidrogênio/farmacologia , Cremes Dentais/farmacologia , Escovação Dentária , Dentina , Animais , Bovinos
8.
Int Dent J ; 73(3): 370-376, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36075760

RESUMO

OBJECTIVES: This study aimed to evaluate implants from different manufacturers and determine whether implant-healing abutment interface has a significant impact on implant seal. METHODS: An air-injection pressure measurement test was performed on implants with either line-contact (modified TSIII [TSM] and Bone Level Tapered [BLT]) or partial face-contact (BlueDiamond [BD], SuperLine [SL], ISII, and UFII) interface design from 6 different manufacturers. Forty implants per implant type were analysed. Pressure data were evaluated with Kruskal-Wallis test and Dunn's post hoc analysis (statistical significance was set at P < .05). RESULTS: BLT implants leaked when the mean pressure was increased to 199.9 kPa. The following implants showed mean leakage pressures of 182.9 (TSM), 157.4 (BD), 112.9 (SL), 101.8 (ISII), and 30.6 (UFII). There was a significant difference between line-contact and partial face-contact implants (P < .001). CONCLUSIONS: The implant interface design has a significant impact on implant microbial leakage. Implants with a line-contact interface exhibited a higher resistance to leakage than those with partial face-contact.


Assuntos
Implantes Dentários , Infiltração Dentária , Humanos , Dente Suporte , Propriedades de Superfície
9.
Biomed Res Int ; 2022: 8720412, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35958810

RESUMO

Miniscrew has been used widely as an effective orthodontic anchorage with reliable stationary quality, ease of insertion and removal techniques, immediate or early loading, flexibility in site insertion, less trauma, minimal patient cooperation, and lower price. Nonetheless, it is not free of complications, and they could impact not only the miniscrew success rate but also patients' oral health. In this article, literature was searched and reviewed electronically as well as manually to evaluate the complications of orthodontic miniscrew. The selected articles are analyzed and subcategorized into complications during and after insertion, under loading, and during and after removal along with treatment if needed according to the time. In addition, the noteworthy associated factors such as the insertion and removal procedures, characteristics of both regional and local anatomic structures, and features of the miniscrew itself that play a significant role in the performance of miniscrews are also discussed based on literature evidence. Clinicians should notice these complications and their related factors to make a proper treatment plan with better outcomes.


Assuntos
Procedimentos de Ancoragem Ortodôntica , Parafusos Ósseos/efeitos adversos , Humanos , Procedimentos de Ancoragem Ortodôntica/efeitos adversos , Procedimentos de Ancoragem Ortodôntica/métodos
10.
Dent Mater J ; 41(5): 731-740, 2022 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-35793939

RESUMO

The relative dentin abrasivity-profilometry equivalent values were compared using non-contact profilometry with three subtypes of regular toothpaste and two subtypes of whitening toothpaste containing sodium bicarbonate and 35% hydrogen peroxide. Bovine dentin specimens were assigned to six groups: regular toothpaste (R): R1 (BAMBOO SALT GUM OINTMENT); R2 (MEDIAN TARTAR ORIGINAL); R3 (PERIOE Alpha), Reference slurry: RS (calcium pyrophosphate), whitening toothpaste (W): W1 (NET. WT); W2 (Vussen 28 WHITENING). Relative dentin abrasion-profilometry equivalent (RDA-PE) was determined by brushing 10,000 times (n=8). The pH of the toothpaste was measured (n=5) and the abrasive constituents of the toothpaste was analyzed by FE-SEM and EDS. The RDA-PE values ranged from 26 to 166, and the pH level ranges were 4.928-9.153. The RDA-PE value of the whitening toothpaste containing hydrogen peroxide was not high compared with that of the regular toothpaste. The RDA-PE values of whitening toothpaste could vary depending on the mechanism and ingredients of the whitening agents.


Assuntos
Clareadores , Abrasão Dentária , Animais , Pirofosfato de Cálcio , Bovinos , Dentina , Hidrogênio , Teste de Materiais , Pomadas , Bicarbonato de Sódio , Escovação Dentária/métodos , Cremes Dentais/farmacologia
11.
Dent Mater J ; 41(5): 767-773, 2022 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-35858791

RESUMO

The microbial leakage at the implant-abutment interface (IAI) is one cause of peri-implant infection that puts long-term implant stability at risk. The present study compared two types of Morse taper implants in terms of sealing performance at the implanthealing abutment interface. Three implant systems, one of which exhibited a partial face-contact design (TSO) and the other two a line-contact design (TSM and BLT), were analyzed in vitro using two quantitative implant leakage measuring techniques: air-injection pressure measurement test and microbial examination. An in-house-developed device was used to determine implant leakage by recording the initial drop in pressure while injecting air through the implant. The microbial examination measured the absorbances of culture mediums in which the inoculated implants were contained. Significant difference was found between the partial face- and line-contact groups (p<0.001). Both tests revealed that partial face-contact implants are more prone to leakage than line-contact implants.


Assuntos
Implantes Dentários , Infiltração Dentária , Meios de Cultura , Dente Suporte , Projeto do Implante Dentário-Pivô , Humanos
12.
Diagnostics (Basel) ; 13(1)2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36611376

RESUMO

Although many studies on bladder cancer and the microbiome have been conducted so far, useful strains at the species level have not yet been identified. In addition, in the case of urine studies, methodological heterogeneity is too great, and in tissue studies, the species level through shotgun analysis has not been revealed, and studies using stool samples have provided only limited information. In this review, we will review all the microbiome studies related to bladder cancer so far through a systematic review.

13.
J Pers Med ; 11(12)2021 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-34945854

RESUMO

Animal studies have shown the interaction between androgens and the gut microbiome directly and indirectly; however, limited evidence from human studies is available. To evaluate the association between prostate-specific antigen (PSA) levels within the normal range, reflective of androgen receptor activity, and the gut microbiota composition, a cross-sectional analysis was performed in 759 Korean men aged between 25 and 78 years with normal PSA levels of ≤4.0 ng/mL. We evaluated the biodiversity of gut microbiota as well as the taxonomic and functional signatures associated with PSA levels using 16S rRNA gene sequencing data. PSA levels within the normal range were categorized into three groups: lowest quartile (G1), interquartile range (G2, reference), and highest quartile (G3). The G3 group had higher microbial richness than the G2 group, although it was dominated by a few bacteria. An increase in Escherichia/Shigella abundance and a reduction in Megamonas abundance in the G3 group were also detected. A U-shaped relationship was observed between the three groups across most analyses, including biodiversity, taxonomic composition, and inferred pathways in the gut microbiota. This study showed different microbiota patterns across PSA levels within the normal range. Further studies are required to elucidate the role of microbiota in regulating PSA levels.

14.
Pharmaceuticals (Basel) ; 14(8)2021 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-34451875

RESUMO

BACKGROUND: The mTOR signaling pathway is inactivated by AMPK's tumor-suppressing function. It is recognized that ubiquitin conjugating enzyme 2O (UBE2O), which directly targets AMPK for ubiquitination and degradation, is intensified in human cancers. METHODS: This study investigated the clinical data about prostate cancer. Examination was also carried out into tissue microarrays (TMA) of human prostate cancer (n = 382) and adjacent non-neoplastic tissues around prostate cancer (n = 61). The TMA slides were incubated with antibodies against UBE2O, and the cores were scored by the pathologist blind to cancer results. RESULTS: Very strong positive correlations were identified between the expression of UBE2O staining and high PSA and pathological stage of prostate cancer. Cox's proportional hazard analysis established correlations between the following: (1) positive surgical margin and biochemical recurrence free survival, (2) PSA grade and clinical recurrence free survival, (3) regional lymph node positive and clinical recurrence free survival, (4) adjuvant treatment and overall survival, and (5) pathological T stage and overall survival. CONCLUSION: There is a positive correlation between the expression of UBE2O staining and prognosis for prostate cancer. Thus, a prostate cancer prognosis can be assessed with the expression of UBE2O staining.

15.
Artigo em Inglês | MEDLINE | ID: mdl-33835912

RESUMO

Soybean pods, separated and enclosed from the outside environment, are considered a suitable place to find new microbes. A Gram-stain-negative, aerobic bacterium, bacterial strain (YB22T) was isolated from the pod of Glycine max (soybean) collected from a rural area in Republic of Korea and characterized by using polyphasic taxonomy. Cells of the strain were rod-shaped (approximately 0.4-0.6 µm wide and 4.0-5.0 µm long), non-flagellated and formed silver-yellow colonies. Cells grew at 25-35 °C (optimum, 28-30 °C), at pH 5.0-9.0 (optimum, pH 7.0) and with 0-2.0% NaCl (optimum, 0 % NaCl). 16S rRNA gene sequencing showed that strain YB22T was phylogenetically closest to the genus Elizabethkingia, and showed highest similarities to Elizabethkingia occulta G4070T (96.7 %), Elizabethkingia meningoseptica ATCC 13253T (96.7 %), Elizabethkingia miricola DSM 14571T (96.6 %), Elizabethkingia bruuniana G0146T (96.5 %), Elizabethkingia ursingii G4122T (96.4 %) and Elizabethkingia anophelis R26T (96.2 %). Average amino acid identity values between strain YB22T and other taxa in the genus Elizabethkingia were all above the threshold range of genus determination. Average nucleotide identity and digital DNA-DNA hybridization values between strain YB22T and other phylogenetic relatives were all found to be below the threshold range for species determination. The respiratory quinone of strain YB22T was menaquinone 6 (MK-6) and the predominant cellular fatty acids were iso-C15 : 0 (47.8 %) and iso-C17 : 0 3-OH (18.5 %). The major polar lipids were phosphatidylethanolamine, four unidentified aminolipids and three unidentified polar lipids. The phylogenetic analysis and physiological and biochemical data showed that strain YB22T should represent a novel species in the genus Elizabethkingia, for which the name Elizabethkingia argenteiflava sp. nov. is proposed. The type strain for this novel species is YB22T (=KCCM 43263T=JCM 32097T).


Assuntos
Flavobacteriaceae/classificação , Glycine max/microbiologia , Filogenia , Técnicas de Tipagem Bacteriana , Composição de Bases , DNA Bacteriano/genética , Ácidos Graxos/química , Flavobacteriaceae/isolamento & purificação , Hibridização de Ácido Nucleico , Fosfatidiletanolaminas/química , Pigmentação , RNA Ribossômico 16S/genética , República da Coreia , Análise de Sequência de DNA , Vitamina K 2/análogos & derivados , Vitamina K 2/química
16.
Nature ; 585(7824): 221-224, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32908262

RESUMO

Platinum is a much used catalyst that, in petrochemical processes, is often alloyed with other metals to improve catalytic activity, selectivity and longevity1-5. Such catalysts are usually prepared in the form of metallic nanoparticles supported on porous solids, and their production involves reducing metal precursor compounds under a H2 flow at high temperatures6. The method works well when using easily reducible late transition metals, but Pt alloy formation with rare-earth elements through the H2 reduction route is almost impossible owing to the low chemical potential of rare-earth element oxides6. Here we use as support a mesoporous zeolite that has pore walls with surface framework defects (called 'silanol nests') and show that the zeolite enables alloy formation between Pt and rare-earth elements. We find that the silanol nests enable the rare-earth elements to exist as single atomic species with a substantially higher chemical potential compared with that of the bulk oxide, making it possible for them to diffuse onto Pt. High-resolution transmission electron microscopy and hydrogen chemisorption measurements indicate that the resultant bimetallic nanoparticles supported on the mesoporous zeolite are intermetallic compounds, which we find to be stable, highly active and selective catalysts for the propane dehydrogenation reaction. When used with late transition metals, the same preparation strategy produces Pt alloy catalysts that incorporate an unusually large amount of the second metal and, in the case of the PtCo alloy, show high catalytic activity and selectivity in the preferential oxidation of carbon monoxide in H2.

17.
Microbiol Resour Announc ; 9(34)2020 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-32816971

RESUMO

Weissella cibaria appears to have broad-spectrum health benefits. Here, we report the genome sequence of Weissella cibaria strain BM2, which was isolated from homemade kimchi; it consists of one circular chromosome of 2,462,443 bp and one plasmid of 11,067 bp. A total of 2,337 coding sequences were predicted, including 2,117 protein-coding sequences and a G+C content of 45.06%.

18.
Dent Mater ; 36(7): 945-958, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32475749

RESUMO

OBJECTIVE: Titanium and its alloys are widely used for dental and medical biomaterials due to their excellent mechanical and biological advantages. After the introduction of direct laser metal sintering (DLMS) 3D printing technology and its use over conventional machine-cut processes, questions remain regarding whether 3D-printed titanium (alloy) devices have similar biological properties to machine-cut counterparts for dental applications. Thus, this work focuses on comparing the biological activities of machine-cut and 3D-printed specimens after optimizing the DLMS 3D-printing conditions in terms of the mechanophysical characteristics. METHODS: The DLMS 3D-printing (as a function of the laser spacing from 30-100µm) and post-surface treatment (as-given or sand-blasted) conditions were optimized using medical-grade Ti-6Al-4V powders in terms of the inner pore amount, mechanical properties, roughness and hydrophilicity. Then, the initial cell adhesion of the optimized DLMS 3D-printed Ti-6Al-4V specimen was compared with that of the machine-cut Ti-6Al-4V specimen against human dermal fibroblasts (hDFs) and mesenchymal stem cells (hMSCs), which are representative of direct-contact cell types of orofacial mucosa and bone, respectively. hMSC differentiation on the specimens was conducted for up to 21 days to measure the osteogenic gene expression and biomineralization. RESULTS: Laser spacings of 30-40µm had fewer inner defects and consequently a higher three-point flexural strength and elastic modulus compared to other larger laser spacings. Depending on the span width (0.3-1mm) in the lattice architecture, the elastic modulus of the 3D-printed cuboid specimen can be further controlled (up to ∼30 times). The sand-blasted specimens after 3D printing revealed lower surface roughness and higher hydrophilicity compared to the as-3D printed specimen, which were considered optimal conditions for biological study. Initial hDF and hMSC adhesion for 12 hr and hMSC differentiation on the surface were comparable between the sand-blasted 3D-printed and machine-cut specimens in terms of adherent cell numbers, vinculin intensity, osteogenic gene expression and biomineralization. SIGNIFICANCE: The optimized DLMS 3D-printed Ti-6Al-4V specimen had similar biological properties to those of the machine-cut counterpart, suggesting the potential usefulness of 3D printing technology for a wide range of dental applications.


Assuntos
Ligas , Titânio , Materiais Biocompatíveis , Humanos , Teste de Materiais , Osteogênese , Impressão Tridimensional , Propriedades de Superfície
19.
RSC Adv ; 10(58): 35318-35328, 2020 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-35515682

RESUMO

Catalytic cascade reactions are strongly desired as a potential means of combining multistep reactions into a single catalytic reactor. Appropriate catalysts composed of multi-reactive sites to catalyze cascade reactions in a sequential fashion are central to such efforts. Here, we demonstrate a bifunctional zeolite catalyst with close proximity of Brønsted and Lewis acid sites through the synthesis of a mesoporous ZrO2[Al]MFI nanosponge (NS). The unique mesopores of the MFI-NS allow the confinement of zirconium oxide clusters (Lewis acid sites, LA) within the few-unit-cell-thin MFI aluminosilicate zeolite wall (Brønsted acid sites, BA). Such a structure is clearly distinct from the conventional MFI zeolite, where the agglomeration of zirconium oxide clusters onto the external surface area within the crystal bulk is not possible, resulting in segregated BA and LA sites on the internal and external zeolite, respectively. By bringing the BA and LA within ZrO2[Al]MFI-NS 30, we uncovered a more efficient catalytic route for the conversion of furfural (100% within 2 h) to γ-valerolactone (GVL) (83%). This route is only evident when the long molecular diffusion path, in the most extreme case of physically mixed ZrO2-(LA) and Al-zeolites (BA) (45% of GVL yield), is eliminated. Unlike the bifunctional ZrO2-Al-beta (GVL yield of 75%), where the BA concentration is greatly compromised at the expense of LA formation, we also show that the ZrO2[Al]MFI-NS is able to maintain a high density and good stability of both types of acids.

20.
Stem Cells Int ; 2019: 1251536, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31772585

RESUMO

The proper choice of dental composite resins is necessary based on the minimal cytotoxicity and antiodontogenesis on human dental pulp stem cells for dental pulp-dentin tissue repair and regeneration. The aim of this study was to evaluate the cytotoxicity and antidifferentiation effects of dental bulk-fill resins, able to be polymerized as a bulk status for filling deep cavity of a tooth by single light curing, against human dental pulp stem cells (hDPSCs) from three compartments corresponding to depth (0-2, 2-4, and 4-6 mm) from the light-curing site. Three bulk-fill composite resins (SDR, Venus bulk-fill (VBF), and Beautifil Bulk Flowable (BBF)) and a conventional flowable composite resin (Filtek Z350 XT flowable restorative (ZFF)) were individually filled into a cylindrical hole (h = 2 mm, Ф = 10 mm), and three compartments (total ~6 mm of height) were combined as a single assembly for light curing. The resin samples from the three layers were separated and eluted in the culture medium. The extracts were exposed to hDPSCs, and cytotoxicity and differentiation capability were evaluated. Depth of cure and surface hardness according to depth were determined. All bulk-fill resins except BBF revealed cytotoxicity from 4 to 6 or 2 to 4 mm, while ZFF was cytotoxic at over 2 mm. Depth of cure was detected from 3.55 to 4.02 mm in the bulk-fill resins (vs. ~2.25 mm in conventional resin), and 80% hardness compared with that of a fully polymerized top surface was determined from 4.2 to 6 mm in the bulk-fill resin (vs. 2.4 mm in conventional resin). Antidifferentiation was revealed at a depth of 4-6 mm in the bulk-fill resin. There was a difference in depth of cytotoxicity and antidifferentiation between the bulk-fill composite resins, which was mainly due to different cure depths and ingredients. Therefore, careful consideration of choice of bulk-fill resins is necessary especially for restoration of deep cavities for maintaining the viability and differentiation ability of dental pulp stem cells.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA